Balance of System

DC Fuse and HolderInverter Fuse Blocks
Our DC Fuse and Holder are extra heavy duty DC Class "T" rated fuses from 110 to 400 A, with "slow blow" characteristics suitable for inverter installations. Protect yourself and your equipment! Includes mounting block, fuse and protective cover. Screw lugs fit bare cable to 4/0.

# 08-58-001 110 A
# 08-58-002 200 A
# 08-58-003 300 A
# 08-58-004 400 A

Options:
# 08-16-137 F-110 replacement fuse
# 08-16-138 F-200 replacement fuse
# 08-16-139 F-300 replacement fuse
# 08-16-140 F-400 replacement fuse
Inverter Size
Fuse Rating (A)
(W)
12 V
24 V
48 V 
1000
200
110
1500
200
110
110
2000
300
200
110
2500
300
200
110
3000
400
300
200
4000
300
200
5500
200


Mega/ AGM Safety Fuse BlockMEGA®/AMG® Safety Fuse Block
The MEGA®/AMG® Safety Fuse Block uses readily available MEGA®/AMG® fuses. This fuse type is popular because it is an economical way to achieve circuit protection up to 250 A, with a 2000 A interrupting capacity. Maximum operational voltage 32 VDC.

# 03-45-009 Fuse Block Assy, Mega-Amp, Excl Fuse

Fuses:
# 03-45-016 Fuse, Mega Series, 32 V, 150 A
# 03-45-017 Fuse, Mega Series, 32 V, 200 A
# 03-45-018 Fuse, Mega Series, 32 V, 250 A

Inverter Size
Fuse Rating (A)
(W)
12 V  
24 V  
1000
200  
100  
1500
200  
100  
2000
250  
150  
(W)
12 V  
24V  
Fuse Block 32 VDC # 03-45-010 Six circuit, common source, fuse block with cover. Max 30 A per circuit, 32 VDC. Accepts ATO® or ATC® fuses, not supplied.

Fuse block 30 A, 32 VCC

# 03-45-015
Six circuit, independent source, fuse block with cover. Max 30 A per circuit, 32 VDC. Accepts ATO® or ATC® fuses, not supplied.


600 VDC Disconnect SquareD600 VDC Disconnects
These 600VDC disconnects were designed specifically for Solar Photovoltaic applications. Can be used in negative, positive grounded systems and also ungrounded DC floating systems for 600 VDC PV applications as transformerless inverters make their way into the market.

• CSA and UL listed for use in 600 VDC systems

# 03-17-016 Fusible 30 A - 600 VDC disconnect switch
# 03-17-017 Fusible 60 A - 600 VDC disconnect switch
# 03-17-018 Fusible 100 A - 600 VDC disconnect switch
# 03-17-019 Fusible 200 A - 600 VDC disconnect switch


MidNite Solar DC disconnectsDC Disconnects
The electrical code requires that inverters be installed with a battery circuit breaker. These powder coated enclosures include the main DC disconnect, din rail for up to five additional DC breakers, grounded bus and 5/16" bonding battery minus stud.
Measures 25 x 13 x 46 cm, 3.2 kgs.

Product #
Model
Description
03-77-006
MNDC125
125 A DC Disconnect, Din Rail
03-77-007
MNDC175
175 A DC Disconnect, Din Rail;
03-77-008
MNDC250
250 A DC Disconnect, Din Rail
Options
03-77-016
MNTBB-NAKED
Bus Bar 4.63, UL CSA Recognized.
03-77-017
MNTBB-R-W
Insulated Bus Bar 4.63, UL ; CSA Recognized
03-77-018
SHUNT-500
Shunt, 500 A


MidNite Solar BreakersBreakers
150 VDC din rail mount breaker (13mm wide) are 1 Lb. All MidNite circuit breakers are rated for 100% continuous duty.
Listed by ETL for US & Canada.

Model #
Product #
Rated Current
Operation Voltage
DIN Rail
Panel Mounted
Description
(A)
(V)
MNEPV2
03-77-033
2
150 VDC
X
Small Size -0.5” Wide
MNEPV4
03-77-035
4
150 VDC
X
Small Size -0.5” Wide
MNEPV6
03-77-036
6
150 VDC
X
Small Size -0.5” Wide
MNEPV8
03-77-037
8
150 VDC
X
Small Size -0.5” Wide
MNEPV9
03-77-038
9
150 VDC
X
Small Size -0.5” Wide
MNEPV10
03-77-021
10
150 VDC&
X
Small Size -0.5” Wide
MNEPV15
03-77-004
15
150 VDC
X
Small Size -0.5” Wide
OBB-20-150VDC-DIN
08-53-169
20
150 VDC
X
Small Size -0.5” Wide
MNEPV30
03-77-012
30
150 VDC
X
Small Size -0.5” Wide
MNEPV50
03-77-013
50
150 VDC
X
Small Size -0.5” Wide
MNEPV60
03-77-014
60
150 VDC
X
Small Size -0.5” Wide
MNEPV63
03-77-015
63
150 VDC
X
Small Size -0.5” Wide
AC or DC BREAKERS
MNEDC05
03-77-030
5
120VAC OR 150VDC
X
Stud – Size 0.75” Wide
MNEDC10
03-77-023
10
120VAC OR 150VDC
X
Stud – Size 0.75” Wide
MNEDC15
03-77-025
15
120VAC OR 150VDC
X
Stud – Size 0.75” Wide
MNEDC20
03-77-026
20
120VAC OR 150VDC
X
Stud – Size 0.75” Wide
MNEDC30
03-77-028
30
120VAC OR 150VDC
X
Stud – Size 0.75” Wide
MNEDC40
03-77-029
40
120VAC OR 150VDC
X
Stud – Size 0.75” Wide
MNEDC50
03-77-031
50
120VAC OR 150VDC
X
Stud – Size 0.75” Wide
MNEDC60
03-77-005
60
120 VAC OR 150 VDC
X
Stud – Size 0.75” Wide
MNEDC80
03-77-032
80
120 VAC OR 150 VDC
X
Stud – Size 0.75” Wide
MNEDC100
03-77-024
100
125 VDC
X
Stud – Size 0.75” Wide
OBB-100-125VDC-PNL
08-53-076
100
125 VDC
X
Stud – Size 1.0” Wide
MNEDC125
03-77-009
125
125 VDC
X
Stud – Size 1.0” Wide
MNEDC175
03-77-010
175
125 VDC
X
Stud -Size 1.5” Wide
MNEDC250
03-77-011
250
125 VDC
X
Stud -Size 1.5" Wide
AC BREAKERS
OBB-15-120VAC-DIN
08-53-061
15
120 VAC
X
Single Pole -0.50" Wide
OBB-15D-240VAC-DIN
08-53-062
15
120/240 VAC
X
Double Pole -1.0  Wide
OBB-20-120VAC-DIN
08-53-063
20
120 VAC
X
Single Pole -0.50 Wide
OBB-20D-240VAC-DIN
08-53-064
20
120/240 VAC
X
Double Pole -1.0" Wide
OBB-25D-240VAC-DIN
08-53-065
25
120/240 VAC
X
Double Pole -1.0"  Wide
OBB-30-277VAC-DIN
08-53-066
30
120 VAC
X
Single Pole -0.5" Wide
OBB-30D-480VAC-DIN
08-53-067
30
120/240 VAC
X
Double Pole -1.0" Wide
OBB-50-277VAC-DIN
08-53-068
50
120 VAC
X
Single Pole -0.5" Wide
OBB-50D-480VAC-DIN
08-53-070
50
120/240 VAC
X
Double Pole -1.0" Wide
OBB-50T-480VAC-DIN
08-53-069
50
120 VAC -3 PHASES
X
Uses 3 Spaces 1.5” Wide
OBB-60-277VAC-DIN
08-53-170
60
120 VAC
X
Single Pole -0.5" Wide


Safety disconnect enclosure - 2 or 4 breakersSafety Disconnect
Electrical code requires that your system has a means of disconnecting power during servicing. The disconnect will cut the charging circuit as required. Two-pole circuit breakers are extra.
# 03-17-001 Safety Disconnect Enclosure - 2 Breaker
# 03-17-002 Safety Disconnect Enclosure - 4 Breaker
# 03-17-003 Load Center - 8 Breaker
# 03-17-004 Load Center - 12 Breaker

Model #
Product #
Rated Current (A)
Operation Voltage (V)
Description
AC/DC SNAP ON BREAKERS
QO115
03-17-005
15
120 VAC or 48 VDC
Single Pole
QO215
03-17-006
15
120/240 VAC or 48 VDC
Double Pole
QO120
03-17-007
20
120 VAC or 48 VDC
Single Pole
QO220
03-17-008
20
120/240 VAC or 48 VDC
Double Pole
QO130
03-17-009
30
120 VAC or 48 VDC
Single Pole
QO230
03-17-010
30
120/240 VAC or 48 VDC
Double Pole
QO140
03-17-011
40
120 VAC or 48 VDC
Single Pole
QO240
03-17-012
40
120/240 VAC or 48 VDC
Double Pole
QO160
03-17-013
60
120 VAC or 48 VDC
Single Pole
QO260
03-17-014
60
120/240 VAC or 48 VDC
Double Pole


Combiner Boxes
OutBack Combiner Box Our code-approved Combiner Boxes provide a convenient, low cost method for the fusing of photovoltaic modules accommodating up to 12 DIN rail breakers for 150 VDC (max) systems, or up to 8 "touch safe" type fuse holders for 600 VDC (max) systems.
# 03-77-001 holds up to 3 DIN breakers
# 03-77-002 holds up to 6 x 150 VDC, or 4 x 600 VDC
# 03-77-003 holds up to 12 x 150 VDC, or 10 x 600 VDC
# 08-53-119 holds up to 16 x 600 VDC
# 08-53-122 holds up to 8 DIN breakers or up to 6 fuseholders
# 08-53-168 holds up to 12 DIN breakers or up to 8 fuse holders

MidNite Solar Arc fault seriesArc Fault - Series PV Disconnecting Combiner
. 200 amp busbars, 5 pole switch.

# 03-77-042 24 Circuit PV Combiner w/ Arc Fault Protection




Fuse Holder
# 08-53-093 Fuse holder 30 A, 600 VDC max

Model #
Product #
Rated Current (A)
Operation Voltage (V)
Description Uses Fuse Holder 
OBF-6-600VDC
08-53-092
6
600 VDC
Uses Fuse Holder
OBF-10-600VDC
08-53-090
10
600 VDC
Uses Fuse Holder
OBF-15-600VDC
08-53-091
15
600 VDC
Uses Fuse Holder

 

Lighting arrestorsMidNite Solar Battery Capacity Meter
This Battery Capacity Meter allows the LEDS to be turned off while retaining the Battery Care memories.
# 03-77-046 MidNiteSolar Battery Capacity Meter



Heavy duty lighting arrestor Lightning arrestors
Heavy duty lightning and surge arrestor for AC or DC circuits and applications, such as photovoltaic systems.
# 03-11-001 Lighting arrestor-AC
# 03-11-002 Lighting arrestor-DC
# 03-11-005 3-Phase 600 VAC Lightning Arrestor, 3 Wire

Surge Protector MidNite SolarSurge Protectors
MidNite Solar offer surge protector devices built for both indoor and outdoor applications. Engineered for both AC and DC electric systems, it provides protection to service panels, load centers or where the SPD (Surge Protection Device) is directly connected to the electronic device requiring protection. To install the SPD, simply pop out a 7/8" diameter knockout and mount the unit on the hole. Dual operating LED Indicators when voltage is present.

# 03-77-022 Protection for charge controllers, off grid PV combiners and 120/ 240 VAC circuits
# 03-77-039 Protection for grid tie PV combiners and inverter input circuits up to 600 VDC

Tigo
Matrix Energy is excited to announce that we now offer Tigo Energy Maximizers. Not comfortable with micro-inverters on your system but need module level optimation and system monitoring and control?

Tigo Energy DC maximizers deliver more power, active management, and enhanced safety for commercial or residential solar systems. It results in a faster return on investment, longer uptime and lower cost of ownership.

Module maximizers are wired to each modules junction box (MC3, MC4, Tyco and H+S Radox versions) and harness maximum power at a 99.5% efficiency modules with an integrated matching impedance technology, which constantly tracks maximum power points and prevents heating areas.

Solar production performance or detected defaults are collected from each maximizer by the Maximizer Management unit via a Gateway, and are sent to a server to be analyzed by the Tigo Energy MaxiManager software. PV system yield is improved monitoring allows a real-time active control and accurate data logging is achieved through intuitive software. The Gateway can interact wirelessly with up to 60 modules within a 50 ft range. The Tigo management unit can be linked to max 6 Gateways (360 modules) via RS-485. First three months monitoring included. Options to extend monitoring software to 5, 10 or 20 years.

Tigo Energy® Installation Training Video
http://www.youtube.com/watch?v=YY4nb69hZLo

# 08-91-010 Tigo Mgmt Unit, Series Config + 1 Gateway + Basic module monitoring
# 08-91-022
Tigo Mgmt Unit Kit W/ Light & Temp Sensors + Basic module monitoring
# 08-91-012
Extra Gateway, for Systems of +60 Modules, or one Roof Angle.
# 08-91-013 Temperature Sensor, Y cable
# 08-91-014 Light Sensor, Y cable


Tigo Energy optimisaters

Product #
Model
Power (W)
Max Voc
Max Isc
Connectors
08-91-001
ES050V300W-3W
300
52
10
MC3 
08-91-002
ES050V300W-4W
300
52
10
MC4 
08-91-003
ES050V300W-5W
300
52
10
TYCO 
08-91-004
ES050V300W-6W
300
52
10
H-S 
08-91-005
ES075V350W-4W
350
75
7.5
MC4 
08-91-006
ES075V350W-5W
350
75
7.5
TYCO 
08-91-007
ES110V300W-3W
300
110
5
MC3 
08-91-008
ES110V300W-4W
300
110
5
MC4 
08-91-009
ES170V300W-4W
300
170
3
MC4 
08-91-023
2ES050300W-4W
300
52
10
MC4 

To know more, contact your Matrix Energy representative or visit -
http://www.tigoenergy.com/our_technology.php

Inverter by-pass switchesInverter By-Pass Switches
Inverter By-Pass Switches allow you to select which source of power connects to your AC distribution panel. Typical installations have either generator or inverter inputs. Interlocked breakers ensure that only one source is connected at a time. Ideal as a manual isolation switch to bypass the inverter. Over current protected.

# 08-17-002 30 A transfer switch
# 08-17-003 60 A transfer switch



Transfer switchesTransfer Switches
These relay-based automatic transfer switches provide switching between two separate power sources. Features include hard wire connections and durable metal enclosure. It can be used in conjunction with another transfer switch for additional power source alternatives. CSA and UL certified

# 08-19-011 30 A auto transfer switch
# 08-19-012 50 A auto transfer switch
# 08-19-013 100 A auto transfer switch

TriMetric TM-2025The TriMetric is used to monitor 12-48 VDC battery systems used in remote homes, RV's or boats that have batteries that store solar, wind, or generator powered chargers. TriMetric's TM-2025 designed to monitor the following:
. "Percent Full" ("State of charge") of your batteries, so you can see if you need to charge them more, or check that overall usage is more than your charging resources.
. Volts of the batteries, for example to check that they are beingless charged at proper voltage.
. Energy going in, or out of your batteries, measured in Amps or Watts, so you can see that your charging sources are charging properly, or how much current your loads are using.
. How many days since the batteries were fully charged: to remind you to not wait too long between fully charging your batteries to maximize their life.
. The TM2025 A is designed to fit an a "double gang" electrical box of appropriate size (not supplied). It has a serial data output of all the "real time" data-which could be used to access data for other control or output in, for example OEM applications.
# 03-22-001

Voltage Controlled SwitchVoltage Controlled Switch
Used for adjustable voltage on / off control of devices. Examples are backup generator control, fluid level control, simple charge controller, simple LVD relay control, battery vent controller etc. 12 - 48 VDC
# 04-25-010 High Active
# 04-25-011 Low Active


Single DC current shuntsSingle DC Current Shunts
Allows measurement of large DC currents with standard volt meters. Brass with insulated base.
# 03-49-009 100 A 100 mV
# 03-49-010 500 A 50 mV


Blocking diodesBlocking Diodes
Protects batteries from reverse current leakage at night through the solar array.
# 16-49-011 Fused Diode Assembly, 3 A
# 16-49-012 Fused Diode Assembly, 6 A

# 03-45-011 Switches a single battery to a single load Continuous Rating 300 Amps Maximum Voltage Rating 48 Volts DC.
# 03-45-012 Dual sensing, automatic charging relay 12/24 volt auto ranging voltage input, up to 120 amps
# 03-45-013 Four position battery selector, 350 A, 32 V, Marine and UL Listed
# 03-45-014 Five position, 8-32 screw terminal. Combines negative and positive buses on one block, CE Certified